A new anilox roller looks perfect on arrival — shiny ceramic, clean journals, engraving you can barely see. But what you cannot see decides whether it prints evenly for years or starts banding in the first month. Before any roller or sleeve goes on press, it should pass three checks: cell volume, total indicated runout (TIR), and surface condition.
Cell volume, measured in BCM (billion cubic microns per square inch), is the amount of ink the roller can carry. Two rollers engraved at the same LPI can carry very different volumes, and a roller whose volume varies across its face will print uneven density from one side of the web to the other. Volume should therefore be measured at several points along the face, not at a single spot. Every ceramic anilox roller and sleeve we ship leaves with a cell volume report, engraved from 30 to 2000 LPI.
Total indicated runout is measured with a dial indicator while the roller turns slowly on its journals. It tells you whether the roller is round and straight, or whether it wobbles as it rotates. A roller with excessive runout bounces against the doctor blade, causing banding, blade chatter and uneven wear — worst at high press speeds. Check TIR on the body and journals, and ask for the measured value, not just a "passed" stamp.
The third check is visual, under magnification. Look for plugged or damaged cells, chipped ceramic at the edges, uneven engraving, and any scoring on the surface. A single damaged band across the face will repeat on every impression. Check the end faces and journals for nicks or corrosion as well. A dense, hard ceramic coating resists wear and holds its volume longer; a soft or porous coating loses volume fast and needs re-engraving sooner.
Ask for a report listing, for your specific roller: LPI and cell geometry (trihelical, open-channel or conventional 60°), cell volume at several points across the face, TIR on body and journals, and a surface-condition note — all tied to the roller's serial number. Keep it with the roller: it is the baseline for every future deep clean or re-inspection. If a supplier cannot provide it, you are buying on trust alone.
How often should a roller already in service be re-measured?
Whenever print density drifts, after any incident such as a blade crash or a dropped roller, and at each scheduled deep clean. As a routine, most printers re-measure once or twice a year, depending on running hours.
Can a roller with excessive TIR be fixed?
Often, yes — if the journals are true and the problem is the ceramic surface, the roller can be reground and re-engraved, as long as enough ceramic thickness remains. A bent journal may need rework first, so measure before you decide.
What makes cell volume drop in service?
Plugged cells from dried ink, gradual wear of the ceramic, and over-aggressive cleaning. Regular cleaning before ink dries, plus periodic volume checks, keeps the loss visible before it shows up on print.
If you are specifying a new roller or sleeve — or wondering whether a current one still meets its original specification — send us your LPI, target volume and roller dimensions, and we will quote to your exact requirements, with a full inspection report on every roller we ship.
Kunshan Qishen Laser Technology Co., Ltd. | Room 10, No.399 Cangye Road, Huaqiao Town, Kunshan City, Jiangsu, China | www.aniloxcylinder.com | WhatsApp +86 18295718941
A new anilox roller looks perfect on arrival — shiny ceramic, clean journals, engraving you can barely see. But what you cannot see decides whether it prints evenly for years or starts banding in the first month. Before any roller or sleeve goes on press, it should pass three checks: cell volume, total indicated runout (TIR), and surface condition.
Cell volume, measured in BCM (billion cubic microns per square inch), is the amount of ink the roller can carry. Two rollers engraved at the same LPI can carry very different volumes, and a roller whose volume varies across its face will print uneven density from one side of the web to the other. Volume should therefore be measured at several points along the face, not at a single spot. Every ceramic anilox roller and sleeve we ship leaves with a cell volume report, engraved from 30 to 2000 LPI.
Total indicated runout is measured with a dial indicator while the roller turns slowly on its journals. It tells you whether the roller is round and straight, or whether it wobbles as it rotates. A roller with excessive runout bounces against the doctor blade, causing banding, blade chatter and uneven wear — worst at high press speeds. Check TIR on the body and journals, and ask for the measured value, not just a "passed" stamp.
The third check is visual, under magnification. Look for plugged or damaged cells, chipped ceramic at the edges, uneven engraving, and any scoring on the surface. A single damaged band across the face will repeat on every impression. Check the end faces and journals for nicks or corrosion as well. A dense, hard ceramic coating resists wear and holds its volume longer; a soft or porous coating loses volume fast and needs re-engraving sooner.
Ask for a report listing, for your specific roller: LPI and cell geometry (trihelical, open-channel or conventional 60°), cell volume at several points across the face, TIR on body and journals, and a surface-condition note — all tied to the roller's serial number. Keep it with the roller: it is the baseline for every future deep clean or re-inspection. If a supplier cannot provide it, you are buying on trust alone.
How often should a roller already in service be re-measured?
Whenever print density drifts, after any incident such as a blade crash or a dropped roller, and at each scheduled deep clean. As a routine, most printers re-measure once or twice a year, depending on running hours.
Can a roller with excessive TIR be fixed?
Often, yes — if the journals are true and the problem is the ceramic surface, the roller can be reground and re-engraved, as long as enough ceramic thickness remains. A bent journal may need rework first, so measure before you decide.
What makes cell volume drop in service?
Plugged cells from dried ink, gradual wear of the ceramic, and over-aggressive cleaning. Regular cleaning before ink dries, plus periodic volume checks, keeps the loss visible before it shows up on print.
If you are specifying a new roller or sleeve — or wondering whether a current one still meets its original specification — send us your LPI, target volume and roller dimensions, and we will quote to your exact requirements, with a full inspection report on every roller we ship.
Kunshan Qishen Laser Technology Co., Ltd. | Room 10, No.399 Cangye Road, Huaqiao Town, Kunshan City, Jiangsu, China | www.aniloxcylinder.com | WhatsApp +86 18295718941